Seitenansicht 160
Driver for Linux -Troubleshooting Section Page 155
1402 SLe message: Command ring <num> timeout
DESCRIPTION: An IOCB command was posted to a ring and did not complete within a timeout based on
R_A_TOV.
DATA: none
SEVERITY: error
LOG: always
MODULE: fcscsib.c
ACTION: This error could indicate a software driver or firmware problem. If no I/O is going through the
adapter, reboot the system. If this problem persists, report this error to Technical Support.
Log Messages - IOCTL Events (1600 - 1699)
elx_mes1600: dfc_ioctl entry
DESCRIPTION: The entry point for processing diagnostic ioctl.
DATA:(1) c_cmd (2) c_arg1 (3) c_arg2 (4) c_outsz
SEVERITY: Information
LOG: LOG_IP verbose
ACTION: None required.
elx_mes1601: dfc_ioctl exit
DESCRIPTION: The exit point for processing diagnostic ioctl.
DATA: (1) rc (2) c_outsz (3) c_dataout
SEVERITY: Information
LOG: LOG_IP verbose
ACTION: None required.
elx_mes1602: dfc_data_alloc
DESCRIPTION: Allocating data buffer to process dfc ioct.
DATA: (1) fc_dataout (2) fc_outsz
SEVERITY: Information
LOG: LOG_IOC verbose
ACTION: None required.
elx_mes1603: dfc_data_free
DESCRIPTION: The data buffer is being freed to process dfc ioct.
DATA: (1) fc_dataout (2) fc_outsz
SEVERITY: Information
LOG: LOG_IOC verbose
ACTION: None required.
elx_mes1604: lpfc_ioctl:error
DESCRIPTION: The SCSI send request buffer size limit was exceeded.
DATA: (1) error number index
SEVERITY: Error
LOG: Always
ACTION: Reduce the application program's SCSI send request buffer size to less then 320K bytes.