Driver for Linux -Troubleshooting Section Page 113
elx_mes0221: FAN timeout
DESCRIPTION: A link up event was received without the login bit set, so the driver waits E_D_TOV for the
Fabric to send a FAN. If no FAN if received, a FLOGI will be sent after the timeout.
DATA: None
SEVERITY: Warning
LOG: LOG_DISCOVERY verbose
ACTION: None required. The driver recovers from this condition by issuing a FLOGI to the fabric.
elx_mes0222: Initial FLOGI timeout
DESCRIPTION:The driver sent the initial FLOGI to fabric and never got a response back.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: Check Fabric configuration. The driver recovers from this and continues with device discovery.
elx_mes0223: Timeout while waiting for NameServer login
DESCRIPTION: Our login request to the NameServer was not acknowledged within RATOV.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: Check the fabric configuration. The driver recovers from this and continues with device
discovery.
elx_mes0224: NameServer Query timeout
DESCRIPTION: Node authentication timeout, node Discovery timeout. A NameServer Query to the Fabric
or discovery of reported remote NPorts is not acknowledged within R_A_TOV.
DATA: (1) fc_ns_retry (2) fc_max_ns_retry
SEVERITY: Error
LOG: Always
ACTION: Check Fabric configuration. The driver recovers from this and continues with device discovery.
elx_mes0225: Device Discovery completes
DESCRIPTION: This indicates successful completion of device (re)discovery after a link up.
DATA: None
SEVERITY: Information
LOG: LOG_DISCOVERY verbose
ACTION: No action needed, informational.
elx_mes0226: Device discovery completion error
DESCRIPTION: This indicates that an uncorrectable error was encountered during device (re)discovery
after a link up. Fibre Channel devices will not be accessible if this message is displayed.
DATA: None
SEVERITY: Error
LOG: Always
MODULE: fcscsib.c
ACTION: Reboot the system. If the problem persists, report the error to Technical Support. Run with