EMC Host Connecivity with Emulex Fibre Channel HBAs and CNAs in the Windows Environment
Installation and Configuration
Figure 131 Scanning for available boot LUNs
If no entries (other than 00) appear, verify the following:
• If multiple adapters are present, verify the adapter selected in
the BIOS utility is the same adapter that currently provides the
I/O path to the storage. (At this point, only one I/O path
should be configured to the boot LUN.)
• For VNX series or CLARiiON systems, verify the single I/O
path points to the SP that owns the boot LUN.
• For FC-SW environments, verify fabric-zoning parameters,
such that a single I/O path exists to the boot LUN. (Refer to
your array software documentation for details.)
• Check the physical Fibre Channel connectivity between the
adapter and array switch (FC-SW environment).
9. Enter the two digits of the starting LUN address, and press Enter.
This setting specifies the LUN address where the utility will begin
scanning for available boot LUNs. For example, entering 0B will
result in the utility scanning from LUN address 0B for available
LUNs, skipping addresses 00 through 0A. In this example,
entering 00 instructs the utility to scan from 00, which is the first
LUN address. This will scan all LUNs visible to the adapter.