1105 TMc message: Config line <num> has illegal The LUN sequence mode.
DESCRIPTION: The specified configuration line has an illegal LUN sequence
mode.
DATA: none
SEVERITY: error config
LOG: always
MODULE: fc<LINUX>fcp.c
ACTION: Check the LUN configuration on the specified configuration line. The LUN
sequence mode is illegal.
1106 TMi message: This config line <num> HBA <num> disabled per LOFF.
DESCRIPTION: The specified configuration line is diasbled.
DATA: none
SEVERITY: information
LOG: LOG_TGTM verbose
MODULE: fc<LINUX>fcp.c
ACTION: If this configuration is not intended, check the LUN configuration on the
specified configuration line. The first member of the configuration structure can be
set to disable the line (LOFF) or enable the line (LON).