elx_mes0224: NameServer Query timeout
DESCRIPTION: Node authentication timeout, node Discovery timeout. A
NameServer Query to the Fabric or discovery of reported remote NPorts is not
acknowledged within R_A_TOV.
DATA: (1) fc_ns_retry (2) fc_max_ns_retry
SEVERITY: Error
LOG: Always
ACTION: Check Fabric configuration. The driver recovers from this and continues
with device discovery.
elx_mes0225: Device Discovery completes
DESCRIPTION: This indicates successful completion of device
(re)discovery after a link up.
DATA: None
SEVERITY: Information
LOG: LOG_DISCOVERY verbose
ACTION: No action needed, informational.