elx_mes0602: IP Response ring <num> out of posted buffers
DESCRIPTION: The IP ring returned all posted buffers to the driver and is waiting
for the driver to post new buffers. This could mean that the host system is out of
TCP/IP buffers.
DATA: (1) fc_missbufcnt (2) NoRcvBuf
SEVERITY: Error
LOG: Always
ACTION: Try allocating more IP buffers (STREAMS buffers or mbufs) of size 4096
and/or increasing the post-ip-buf lpfc configuration parameter. Reboot the system.
elx_mes0603: Xmit Sequence completion error
DESCRIPTION: A XMIT_SEQUENCE command completed with a status error in
the IOCB.
DATA: (1) ulpStatus (2) ulpIoTag (3) ulpWord[4] (4) did
SEVERITY: Warning
LOG: LOG_IP verbose
ACTION: If there are many errors to one device, check the physical connections to
Fibre Channel network and the state of the remote PortID. The driver attempts to
recover by creating a new exchange to the remote device.