elx_mes0435: DID binding entry: node table full
DESCRIPTION: More bindings entries were configured than the driver can handle.
DATA: None
SEVERITY: Error config
LOG: Always
ACTION: Make neccessary changes to the lpfc configuration file so that fewer
bindings are configured.
elx_mes0436: Adapter failed to init, timeout, status reg <status>
DESCRIPTION: The adapter failed during powerup diagnostics after it was reset .
DATA: None
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a hardware or firmware problem. If the problem
persists, report the error to Technical Support.