elx_mes0317: Rsp ring <ringno> get: iotag <iotag> greater then configured
max <fast_iotag> wd0 <irsp>
DESCRIPTION: The assigned I/O iotag is greater than the maximum allowed.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a software driver, firmware or hardware
problem. Report these errors to Technical Support.
elx_mes0318: Outstanding I/O count for ring <ringno> is at max <fast_iotag>
DESCRIPTION: An I/O tag cannot be assigned because none are available. The
maximum number of allowed I/Os are currently outstanding.
DATA: None
SEVERITY: Information
LOG:LOG_SLI verbose
ACTION: This message indicates the adapter HBA I/O queue is full. Typically this
happens when heavy I/O is running on a low-end (3 digit) adapter. We suggest you
upgrade to a higher-end adapter.