EMULEX MODEL 375 SAN STORAGE SWITCH
USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT
EMULEX CORPORATION 48
P
ART NUMBER 00041369-002 REV. B
To assign ports to trunk groups:
1. Click Advanced Functions > Automatic Trunking.
The Automatic Trunking page appears.
2. Select a trunk group for each port by clicking the appropriate Trunk Group option.
3. When finished making changes, click Submit.
Load Balancing
Load balancing builds on the Automatic Trunking functionality by specifying the path that the data uses
to flow between multiple switches. Users can manage the switch’s aggregate bandwidth by manually
distributing traffic across multiple cascade ports as shown below. A cascade port is a port that is
attached to another switch of the same type and configured as a String or Tree Cascade Smart Setting
on the Port Smart Settings page. All data flows through the primary cascade, unless the switch is
configured differently.
Note: Cascade ports must be properly configured before load balancing will work.